Bug-o-systems BVW-1000 Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Bug-o-systems BVW-1000. BUG-O Systems BVW-1000 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
OPERATION MANUAL
BVW-1000
AUTOMATIC WELDING MACHINE
Purchase date
Product serial number
Model
Warning: Installation, operation and maintenance are NOT permitted before
reading this manual carefully.
A DIVISION OF WELD TOOLING CORPORATION
280 TECHNOLOGY DRIVE CANONSBURG, PENNSYLVANIA 15317-9564 USA
PHONE: 1- 412- 331-1776 http://www.bugo.com FAX: 1- 412- 331- 0383
Vista de pagina 0
1 2 3 4 5 6 ... 25 26

Indice de contenidos

Pagina 1 -

OPERATION MANUAL BVW-1000 AUTOMATIC WELDING MACHINE Purchase date: Product serial number: M

Pagina 2

9side of the bench, a control cabinet is equipped to supply a three-phase AC 380V/50Hz power source and supply a single-phase alternating current 220

Pagina 3 - 1. Safety Instruction

10 Fig. 2 Schematic diagram of the windproof welding machine frame During the vertical electrogas welding of large tanks, the windproof welding mach

Pagina 4 - 4. Fire prevention

11four symmetric lifting eye for the lifting of the machine framework. Fig.3 The top platform 2. Transverse walking device for the machine fra

Pagina 5

123. Lighting and smoke exhaustion: In front of and behind the operation position inside of the machine framework, there are AC 220V/50Hz explos

Pagina 6

13operation platform outside of the machine framework, while the exporting gas cylinder is located on the top of the machine framework. 5. Cable bri

Pagina 7

144. Installation Introductions 4.1 Security Notices The equipment installation is forbidden before reading through installation instructions in

Pagina 8 - 2. Technical Specifications

15 Warning: When connecting or disconnecting cables, turn the main power switch to the off position. ● Lifting of the Machine Framework Notice: M

Pagina 9 - 3.2 Configurations

16● Utilize the opening switch on the fuse box to cut off the input power source before operating this equipment. To protect your and other people’s

Pagina 10

17SycnegremEtopPOWERWATER TANKFANLIGHTINGREVERSEFORWARDLOWRAPIDDOWNUPALL TIMEMechanical & Electrical Equipment CO.,LTD214735689 Fig.8. Operation

Pagina 11

188. Speed selection switch CS7 of elevating platform Control the elevating platform to run at a high or low speed. 9. Elevating platform switch

Pagina 12

1 CONTENTS 1. SAFETY INSTRUCTION...2 2. TECHNICAL SPECIFICATIONS...

Pagina 13

195. Maintenances Security Notices The equipment maintenance is forbidden before reading through maintenance instructions in this manual. Bewar

Pagina 14 - Operation

20  Examine the Cables and the air hole -----Examine the damage condition of the cables and the air hole.  Examine the Operation Noise -----Ex

Pagina 15 - 4.2 On-site Installation

216. Fault Causes and Solutions Security Notices If some faults occur on the equipment, repairs must be carried out. Only if the debugging is fin

Pagina 16 - 4.3 Operation Instructions

22The frequency gives an alarm and switches off output. Reset the frequency converter and check alarm cause. The platform has run to the limit switc

Pagina 17

237. Welding System Connection Diagram: MDSWater Cooling CableWelding CableWire FeederWork Piece Gas CylinderWaterPower SourceWater Cooling TorchRai

Pagina 18 - ALL TIME

248. Electrical Schematic Diagram Diagram of Machine Frame Control system:           

Pagina 19

25 9. Installation Dimension and Structure Diagram Dimension diagram of EGW

Pagina 20 - 5. Maintenances

21. Safety Instruction In the Bug-O/All-Time Mechanical & Electrical Equip. Co. LTD, equipment is designed and manufactured based on the saf

Pagina 21

3I. In the course of the aloft work, the worker should use safety to avoid dropping. 2. Beware of the arc light A. When you observe the arc light

Pagina 22 - Warning

4lead to fire hazard. In addition, the welding operation near the pipeline for the fuel gas should be forbidden and the fire fighting equipment shoul

Pagina 23

5will be used or is being used. F. You can obtain the P-1 “Safe Handling of Compressed Gas in Containers” published by CGA from the compressed gas o

Pagina 24

68. Electromagnetic fields are harmful to human bodies A. The current flowing through any conductors will generate a electromagnetic field (EMF), th

Pagina 25 -           

72. Technical Specifications Serial number Items Parameters 1 Power supply scope 240V/380V/440V/3ph/50/60HZ 2 Suitable environment and climate

Pagina 26 - Diagram

83. Brief Introduction of Products 3.1 Product Overview EGW-BUG automated vertical welding machine, which is designed and manufactured by the Bug-OAl

Comentarios a estos manuales