Selecting Type 6-4 allows the speed to change to a fraction of the set speed. Display will read “Speed %”, and
data entry is accepted from 1 to 99. Entering 0 or just return will make the speed 100%, which is the same as
set speed.
When the program reaches a Type 6-4 segment while running, the speed will change to the percent entered,
and continue at this setting until there is a later Type 6-4 segment which changes it to another % setting or back
to 100 %.
Note: If Type 6-3 has been set for Hi (rapid traverse) then this setting will cut down the Hi speed to the same
percent.
Settings below 10% are not recommended.
SET % SPEED, FRACTION OF SET SPEED: TYPE 6, QUADRANT 4